READ AND KEEP THIS MANUAL FOR REFERENCE
45084A
Printed in Canada 12-06-2015
OWNER’S MANUAL
1600 INSERT (OB01601 model)
US ENVIRONMENTAL PROTECTION
AGENCY PHASE II CERTIFIED WOOD
INSERT
OREGON DEPARTEMENT
ENVIRONMENTAL QUALITY
Verified and tested following
ULC S628, UL 907, UL 1482 Standards by an
accredited laboratory
Manufactured by: STOVE BUILDER INTERNATIONAL INC
.
250, rue de Copenhague, Saint-Augustin-de-Desmaures (Quebec) G3A 2H3
After-sale service: 418-908-8002 E-mail: tech@sbi-international.com
www.osburn-mfg.com
This manual is available for free download on the manufacturer’s web site. It is a copyrighted
document. Re-sale is strictly prohibited. The manufacturer may update this manual from time to
time and cannot be responsible for problems, injuries, or damages arising out of the use of
information contained in any manual obtained from unauthorized sources.
Seitenansicht 0
1 2 3 4 5 6 ... 24 25

Inhaltsverzeichnis

Seite 1 - 1600 INSERT (OB01601 model)

READ AND KEEP THIS MANUAL FOR REFERENCE 45084A Printed in Canada 12-06-2015 OWNER’S MANUAL 1600 INSERT (OB01601 model) US ENVIRONMENTAL PRO

Seite 2 - TABLE OF CONTENTS

10MINIMUM MASONRY OPENING, CLEARANCES TO COMBUSTIBLES, AND FLOOR PROTECTOR

Seite 3 - INTRODUCTION

11 MINIMUM MASONRY OPENING MAXIMUM STANDARD FACEPLATE MAXIMUM LARGE FACEPLATE F 22.125" (562 mm) 29" (737 mm) 32" (813 mm) G 2

Seite 4 - TECHNICAL SPECIFICATIONS

12VENTING REQUIREMENTS The flue is a critical component to a satisfactory installation. Your insert will attain its best performanc

Seite 5 - INSTALLATION

13INSTALLATION INSTRUCTIONS 1. Inspect the fireplace according to the safety information and fireplace requirements and have it cleaned and/or upgra

Seite 6 - DOOR OVERLAY INSTALLATION

144. POSITIONING THE UNIT: The more extended the insert, the greater the heat transfer to the room. When installed as an extended inse

Seite 7 - DOOR ADJUSTMENT

155. If lag-bolts and anchors are to be used to secure the insert, the hole locations should be marked with the unit in place. Remove

Seite 8

167. INSTALLATION ON FACEPLATE: Attach the mitred corners of trim together using the corner brackets. Slide the assembled trim over the edge of th

Seite 9

1710. Push the air control (A) in, all the way. Slide the adjustable faceplate sleeve back into its original location until the faceplate fi

Seite 10 - FLOOR PROTECTOR

18OPERATION Your heating unit was designed to burn wood only; no other materials should be burnt. Wastes and other flammable materials should n

Seite 11

19Smaller pieces of wood will dry faster. All logs exceeding 6" in diameter should be split. The wood should not be stored directly on the gro

Seite 12 - VENTING REQUIREMENTS

2 TABLE OF CONTENTS TECHNICAL SPECIFICATIONS ... 4 INSTALLA

Seite 13 - INSTALLATION INSTRUCTIONS

20HEATING Controlled combustion is the most efficient technique for wood heating because it enables you to select the type of combustion you want for

Seite 14

21CREOSOTE FORMATION AND NEED FOR REMOVAL When wood is burned slowly, it produces tar and other organic vapours, which combine with expelled moistur

Seite 15

22MAINTENANCE Your OSBURN insert is a high efficiency insert and therefore require little maintenance. It is important to perform a visual inspection

Seite 16

23BAFFLE INSTALLATION All firebrick and ceramic wool baffles must be properly in place for correct burning operation. Have any dama

Seite 17

24SECONDARY AIR TUBE REPLACEMENT 1. Remove cotter pin at left end of tube. 2. Slide tube to right and lower tube end below left plenum. 3. Slid

Seite 18 - OPERATION

25 OSBURN LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original retail purchaser and is not transferable. This w

Seite 19

3 INTRODUCTION SBI INC., one of the most important wood stove and fireplace manufacturers in Canada, congratulates you on your purchase and wi

Seite 20 - RELOADING

4 TECHNICAL SPECIFICATIONS Combustible: Wood Recommended surface: Up to 1800 square feet Heating Capacity* : E.P.A :

Seite 21 - ASH DISPOSAL

5 INSTALLATION SAFETY NOTICE • IF THIS INSERT IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLAT

Seite 22 - MAINTENANCE

6 DOOR OVERLAY INSTALLATION In order to complete the assembly of your Osburn 1600 wood insert, you need to install the door overlay. See figure 1 be

Seite 23 - BAFFLE INSTALLATION

7 DOOR ADJUSTMENT In order for your insert to operate properly, the door should be adjusted periodically to provide an air tight fit.

Seite 24 - Model Type of tube

8 PRE-INSTALLATION REQUIREMENTS MASONRY & ZERO CLEARANCE REQUIREMENTS The masonry fireplace must meet the minimum code requirements, or NFPA 21

Seite 25

9 4. CHIMNEY CAPS: Mesh type chimney caps must have provision for regular cleaning, or the mesh should be removed to eliminate the potential of plu

Kommentare zu diesen Handbüchern

Keine Kommentare