READ AND KEEP THIS MANUAL FOR REFERENCE
45127A
Printed in Canada 12-06-2015
OWNER`S MANUAL
1100
(OB01111 model)
US ENVIRONMENTAL PROTECTION AGENCY PHASE II CERTIFIED WOODSTOVE
STOVE BUILDER INTERNATIONAL INC
.
250, de Copenhague,
Saint-Augustin-de-Desmaures
(Quebec), Canada G3A 2H3
After-sale service: 418-908-8002
E-mail: tech@sbi-international.com
Verified and tested following
ULC S627 and UL 1482 Standards by
an accredited laboratory
www.osburn-mfg.com
This manual is available for free download on the manufacturer’s web site. It is a
copyrighted document. Re-sale is strictly prohibited. The manufacturer may update this
manual from time to time and cannot be responsible for problems, injuries, or damages
arising out of the use of information contained in any manual obtained from unauthorized
sources.
Seitenansicht 0
1 2 3 4 5 6 ... 35 36

Inhaltsverzeichnis

Seite 1 - (OB01111 model)

READ AND KEEP THIS MANUAL FOR REFERENCE 45127A Printed in Canada 12-06-2015 OWNER`S MANUAL 1100 (OB01111 model) US ENVIRONMENTAL PROTECTION AGEN

Seite 2 - INTRODUCTION

10 FIGURE 1.3 Clearances to combustible materials and floor protection

Seite 3

11 Floor protector If the stove is to be installed on top of a combustible floor, it must be guarded by a non combustible materi

Seite 4 -

12 TYPE OF PROTECTION Reducing Clearances With Shielding Sides and Rear/Back Top Sheet metal, a minimum of 0,024" (0,61mm) spaced out at least

Seite 5 - INSTALLATION REQUIREMENTS

13 Graphic 1 A- Minimum clearance required between the appliance and an unshielded combustible ceiling. B- 20 in. (500 mm) minimum; C- 1 in.

Seite 6 - REQUIREMENTS

14 Graphic 2 A- 1 in.(25 mm) minimum; 1- Combustible wall; 2- Non-combustible spacers; 3- 0.024’’ (0.61mm) sheet metal. Graphic 3 A- 1 in. (2

Seite 7 - INSTALLATION

15 Graphic 5 A- 1 in. (25 mm) minimum; 1- Combustible wall; 2- Non-combustible spacers; 3- Brick. Graphique 6 A- 1 in. (25 mm) minimum; 1-

Seite 8 - DOOR OVERLAY INSTALLATION

16 CHIMNEY SYSTEM DEFINITIONS For clarity, the following definitions should be used with respect to these instructions: A chimney system consists

Seite 9

17 RESIDENTIAL CLOSE CLEARANCES CHIMNEY SYSTEM In addition to the requirements of section 1.6.2.1 the following components are required

Seite 10

• The connector must not pass through any combustible material, nor may it pass through a concealed space (such as an attic, roof space,

Seite 11

19 • The assembly should be as short and direct as possible between the stove and chimney (See figure 2.4 (A)). The use of two 45 degr

Seite 12 - With Shielding

2 INTRODUCTION SBI INC., one of the most important wood stove and fireplace manufacturers in Canada, congratulates you on your purchas

Seite 13 - Graphic 1

20 Figure 1.6 – Chimney height EXTERIOR CHIMNEY Chimneys constructed outside of the home on an exterior wall should be avoided if possible, espec

Seite 14 - Graphic 4

21 TYPICAL TYPES OF CHIMNEY SYSTEMS There are basically two types of chimney systems; one employs an existing masonry chimney, while th

Seite 15 - Graphique 6

22 Figure 1.8 Connections to a Factory Built Chimney (Interior Shown) Figure 1.9 Connection to a Factory Built Chimney (Exterior Shown)

Seite 16 - CHIMNEY SYSTEM

23 OPERATION SAFETY INFORMATION 1. This stove is designed for safe operation WHEN BURNING CORDWOOD ONLY. Altering or modifying the unit o

Seite 17 - CHIMNEY CONNECTOR

24 10. Never operate the stove with the door open, or cracked slightly open, except briefly during the lighting operation, and during refuelli

Seite 18

25 SIMPLE WOOD MOISTURE TEST Add one large piece of wood to the top of an established fire. If it starts to burn on three sides. Within one minute

Seite 19 - CHIMNEY SYSTEMS

26 Open the draft control (located on the front of the stove) fully by moving it from the left to the right, as shown in Figure 2.1 and as indicated

Seite 20 - EXTERIOR CHIMNEY

27 MAINTAINING THE FIRE Your Osburn stove will work best if a thick bed of hot embers is maintained in the bottom of the firebox, a

Seite 21

28 (OPTIONAL) BLOWER INSTALLATION AND OPERATION 1. Allow the stove to reach operating temperature (approximately one hour), before turn

Seite 22

29 MAINTENANCE CARE AND CLEANING Clean the stove frequently so that soot, ash and creosote do not accumulate. Do not attempt to clean the stove,

Seite 23 - OPERATION

3 TABLE OF CONTENTS INTRODUCTION ...

Seite 24 - ORDWOOD

30 4. Clear the ashes from the area where the plug normally sits so that it will properly seat against the opening edges; tap it down with

Seite 25 - LIGHTING A FIRE

31 CHIMNEY CLEANING Regular chimney maintenance, as well as good burning practices, are required to prevent chimney fires. The chi

Seite 26

32 BAFFLE INSTALLATION AND BRICK NOTES Follow these instructions to remove the baffle: 1. Lift the front bricks over the front of baffle support

Seite 27 - MAINTAINING THE FIRE

33 BRICK LAYOUT Figure 3.3 SECONDARY AIR TUBE REPLACEMENT (See Figure 3.4) 1. Remove cotter pin at LH end of tube. 2. Slide tube to right

Seite 28

34 TROUBLESHOOTING Symptom Possible Cause Corrective Action I Smoke in room 1. Down draft 1. Upgrade chimney 2. Chimney blocked

Seite 29 - MAINTENANCE

35 SPECIFICATIONS FUEL TYPE Dry cordwood TEST STANDARDS 1. ULC S627 (CSA B366.2) & UL 1482 residential and mobile home.

Seite 30

36 OSBURN LIMITED LIFETIME WARRANTY The warranty of the manufacturer extends only to the original retail purchaser and is not transferable. This w

Seite 31 - CHIMNEY CLEANING

4 OVERALL STOVE DIMENSIONS Figure 1

Seite 32

5 INSTALLATION REQUIREMENTS In Canada the CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment and the CSA C22.1 Canadian Na

Seite 33 - BRICK LAYOUT

6 MANUFACTURED (MOBILE) HOME INSTALLATIONS – ADDITIONAL REQUIREMENTS 1. The stove must be bolted to the floor (secure the unit by prying out the t

Seite 34 - TROUBLESHOOTING

7 INSTALLATION When installed and operated as described in these instructions, the Osburn 1100 wood stove is suitable for use as a freestan

Seite 35 - SPECIFICATIONS

8 DOOR OVERLAY INSTALLATION In order to complete the assembly of your freestanding Osburn 1100 wood stove, you need to install the door overlay. Se

Seite 36

9 CLEARANCES TO COMBUSTIBLES AND FLOOR PROTECTOR To install your appliance correctly, it is extremely important to respect all clearances to any co